- ELECTRICAL PRODUCT
- FIXED GAS AND FLAME DETECTION SOLUTIONS
- GAS PRODUCT
- CONTRIVE BURNER CONTROL DEVICE
- DUNGS GAS COMPONENTS
- ACCESSORIES
- BALL VALVE
- BURNER MANAGEMENT SYSTEMS AUTOMATIC BURNER CONTROLS
- DOUBLE SOLENOID VALVES
- ELECTRO PNEUMATIC VALVES
- FILTER
- GASMULTIBLOC® MULTIFUNCTIONAL GAS CONTROLS
- MOTOR BUTTERFLY VALVES AND ACTUATORS
- PRESSURE REGULATORS
- PRESSURE SWITCHES FOR GAS AND AIR
- SOLENOID VALVES
- SYSTEM ENGINEERING GAS TRAINS - DUNGSHeatEngine
- VALVE PROVING SYSTEMS LINE LEAKAGE TESTERS-LABORATORY - KITCHEN
- View All
- ECLIPSE BURNER PARTS
- ECONEX GAS TRAIN PRODUCT
- ACCESSORIES FOR GEAR MOTORS
- AIR AND GAS BUTTERFLY VALVE
- DIAL PRESSURE GAUGE
- ELECTRIC ACTUATORS
- ENGINEERED GAS SKID & VALVE TRAIN - GAS PRESSURE REDUCTION STATION
- FLAME SUPERVISION - BURNER CONTROL
- FLAME SUPERVISION - UV DETECTION
- GAS BALL VALVE
- GAS FILTER SERIES (FE)
- GAS PRESSURE REGULATOR
- GAS PRESSURE SWITCH
- GAS SOLENOID & SHUT OFF VALVE
- LINEAR CONTROL VALVE SERIES (MPV)
- MODULATING CONTROL VALVE SERIES (MDV-B1..., B1... E)
- MODULATING CONTROL VALVE SERIES (MDV-D1)
- MOTORIZED BUTTERFLY VALVES ELECTRONIC OR PNEUMATIC ACTUATOR
- NEEDLE VALVE
- PACKAGED VALVE TRAINS - GAS SOLENOID & SHUT OFF VALVE
- SAFETY RELIEF VALVE
- SOLENOID BUTTERFLY VALVE SERIES (BFVS)
- TURBINE METER
- TWO-WAY MANUAL PRESSURE COCK WITH BLEED-OFF
- VALVE PROVING SYSTEM
- View All
- ENOLGAS BONOMI VALVE & ACTUATOR
- GAS BURNER COMTHERM UK
- AIR HEATER (AHP)
- AIR HEATER (HEF)
- AIR HEATER (HEM)
- AIR HEATER (HET)
- COMTHERM EK BURNER
- COMTHERM PROCESS CONE (PC) BURNER
- COMTHERM PROCESS PAK (PP) BURNER
- COMTHERM RECIRCULATION SIDE-PLATE (RSP) BURNER
- COMTHERM SIDE-PLATE (SP) BURNER
- COMTHERM TF IMMERSION BURNER
- COMTHERM TFR IMMERSION BURNER
- DIRECT FIRED AIR HEATER
- FUME INCINERATION BURNER
- PROCESS - HEAT NORMAL CAPACITY (PH)
- PROCESS - HEAT NORMAL CAPACITY (PHC)
- View All
- GAS BURNER SANTIN ITALY
- GAS BURNER SELAS USA
- GECA GAS TRAIN EQUIPMENT
- HONEYWELL
- MAXON BURNER PARTS
- MEDENUS GAS TRAIN PRODUCT
- MTI GAS DETECTOR
- POLIX VALVE
- SIEMENS BURNER PARTS
- YETEN COMBUSTION
- View All
- MECHANICAL PRODUCT
- PROCESS MEASUREMENT AND CONTROL
- THERMOPLASTIC SOLUTIONS
- STUEBBE AERATION & VENT VALVES
- STUEBBE BALL VALVES
- STUEBBE BUTTERFLY VALVES
- STUEBBE CHEMICAL PUMP
- STUEBBE DIAPHRAGM VALVES
- STUEBBE DISPLAY AND CONTROL UNIT
- STUEBBE LEVEL MEASUREMENT
- STUEBBE LIQUID FLOWMETERS
- STUEBBE PRESSURE REDUCING VALVES
- STUEBBE PRESSURE RELIEF VALVES
- STUEBBE PRESSURE SENSOR
- STUEBBE WATER JET PUMP
- View All
VALVE PROVING SYSTEM LDU
|
VALVE PROVING SYSTEM LDU |
The LDU11 valve proving system is designed for use with shutoff valves in connection with gas burners and gas appliances. In the event of inadmissible leakage, the system prevents the burner from starting up.
The LDU11 system conforms to the requirements of EN 1643 covering automatic shutoff valves for use with gas burners and gas-fired appliances to EN 161, class A and pressure switch to EN 1854.
The Siemens LDU11 gas valve leak test control checks for leakage through the shutoff valves prior to burner start-up and/or immediately after burner shutdown. The cost effective, easy to install LDU11 adds a substantial degree of safety to any combustion system.
-
Checks both shutoff valves for leakage
-
Improves system safety
-
No inlet gas pressure limitations
-
Global approvals
-
Easy-to-read dial indicates progress of test program
The LDU11 is designed for automatic gas valve proving (leakage test) based on the pressure proving principle. It is for use on gas-fired combustion plant with or without vent pipe to atmosphere. In the case of plants with no vent pipe where EN standards apply, the notes given in «Connection examples without vent pipe to atmosphere» must be observed.
Used in connection with 1 or 2 commercially available pressure switches, valve proving is automatically initiated with every burner startup, either
-
prior to burner startup
-
during the prepurge time if it lasts a minimum of 60 seconds
-
immediately after a controlled shutdown, or
-
on completion of the burner control’s control sequence, e.g. at the end of the
-
postpurge time
The valve proving test is based on the 2-stage pressure proving principle:
1. The valve on the mains side is tested by evacuating the test space and by monitoring the atmospheric pressure in it.
2. The valve on the burner side is checked by pressurizing the test space and by monitoring the gas pressure.
If the pressure increases excessively during the first test phase called «Test1», or decreases excessively during the second test phase called «Test2», the LDU11. will inhibit burner startup and initiate lockout. In that case, the lockout reset button will light up to indicate the fault. Remote indication of the fault is also possible. A program indicator, which stops whenever a fault occurs, indicates which of the valves is leaking. The LDU11 can be reset either on the unit itself or via an electric remote reset facility.
Type of LDU:
Download Files
- English-n7230en.pdf (168.61 KB)
- LDU11.x23Ax7-Drawing-.pdf.pdf (43.3 KB)
- AGM11-Drawing-.pdf.pdf (59.61 KB)
- Valve_Proving_System_LDU.pdf (627.54 KB)